Purchase of One (1) Liquid Chromatography System
Public summary
Generated or condensed from imported source text. Verify before bidding.
AAFC appears to be seeking one liquid chromatography (LC) system for its Kentville Research and Development Centre in Nova Scotia. The system is intended for proteomics applications and must support nano-flow operation and seamless coupling to mass spectrometry. Key requirements include: - Flow rates of at least 200 nL/min to 100 µL/min without a flow splitter. - Maximum operating pressure of at least 15,000 psi. - Operation across pH 2–10. - Two-dimensional LC capability, including trapping, switching valves, solvent handling, and related components. - Unattended operation for up to 96 hours with diagnostic information available through the control software. - Solvent storage for up to three eluents. - Micro-binary solvent delivery, automated priming, solvent conditioning, compressibility compensation, and an integrated active wash system. - Autosampling from 0.1 µL to 100 µL, multiple injection modes, 48- or 96-position plates, temperature control from 4°C to 40°C, and a temperature-controlled column chamber. - Compliance with the Canadian Electrical Code and CSA certification upon delivery. The procurement is reserved exclusively for suppliers already pre-qualified under Supply Arrangement E60PV-19EQUI for laboratory and scientific equipment. Suppliers that are not current holders of this arrangement cannot submit an evaluated bid for this requirement. Businesses interested in future opportunities may review solicitation E60PV-19EQUI/D through Canada Buys (SAP Ariba) and apply to qualify under the arrangement. The notice lists October 19, 2026 at 2:00 p.m. as the publication closing date, but it specifically states that invited suppliers must rely on the solicitation documents for the actual bid closing date. The procurement strategy indicates that award is expected to go to the responsive invited supplier meeting all mandatory technical criteria and offering the lowest aggregate price. A potentially interested business should first confirm that it holds Supply Arrangement E60PV-19EQUI, obtain the complete solicitation and technical response forms, verify every mandatory specification and certification requirement, and confirm the applicable closing date and submission process. Always verify the official tender notice and solicitation documents on Canada Buys before preparing or submitting a bid. Bid Maple is not affiliated with the Government of Canada.
Requirement preview
A profile unlocks the full bid checklist and match explanation.
- The tender appears reserved exclusively for suppliers currently pre-qualified under Supply Arrangement E60PV-19EQUI for laboratory and scientific equipment, parts and accessories, services and supplies.
- Suppliers without Supply Arrangement E60PV-19EQUI cannot submit a bid; bids from non-pre-qualified suppliers will not be evaluated.
- The procurement is for one (1) liquid chromatography system for Agriculture and Agri-Food Canada’s Kentville Research and Development Centre.
- The LC system must include an LC solution suitable for proteomics, such as a nano-flow LC system for peptide sample preparation and separation, designed for seamless coupling to a mass spectrometer.
Source description preview
Imported source text may contain formatting from the original notice.
Tendering Procedures: Invitation to tenders following instructions on the Supply Arrangement Competitive Procurement Strategy: Contract against the SA will be awarded to the supplier responding to all mandatory technical criteria and with the lowest price.Comprehensive Land Claim Agreement: No Nature of Requirements: Laboratory and Scientific Equipment, SA E60PV-19EQUI for the purchase of : One (1) Liquid Chromatography System Agriculture and Agri-Food Canada, Kentville Research and Development Centre THIS REQUEST IS RESERVED FOR HOLDERS OF SUPPLY ARRANGEMENT # E60PV-19EQUI ONLY, FOR THE PURCHASE OF LABORATORY AND SCIENTIFIC EQUIPMENT, PARTS AND ACCESSORIES, SERVICES AND SUPPLIES. Only Suppliers currently pre-qualified on Supply Arrangement E60PV-19EQUI have been invited to bid. As a requirement of the Supply Arrangement, this notice is published on Government Electronic Tendering Service (GETS) for a period of 40 calendar days. The closing date published on this notice identifies how long the notice will be published. For the closing date of any solicitation under the supply arrangement, invited suppliers should refer to the solicitation documents. Suppliers that do not have a Supply Arrangement for the supply of Laboratory and Scientific Equipment, Parts and Accessories, Services and Supplies with Public Works and Government Services Canada, cannot submit a bid. Any bids received from suppliers not pre-qualified on the Supply Arrangement will not be evaluated. Suppliers may qualify under Supply Arrangement E60PV-19EQUI for Laboratory and Scientific Equipment, Parts and Accessories, Services and Supplies, at any time. Interested suppliers should download solicitation document E60PV-19EQUI/D from Canada Buys (SAP Ariba) and submit a response as per the requirements of the Request for Supply Arrangement. The responsive bidder already holding a Supply arrangement for Laboratory and Scientific Equipment, Parts and Accessories, Services and Supplies from Public Works and Government Services Canada who meets the mandatory technical criteria with the lowest aggregate price will be recommended for contract award.The mandatory technical criteria are: Liquid Chromatography (LC) System a. The LC system must be supplied with an LC solution suitable for proteomics, such as a nano-flow LC system for peptide sample preparation and separation, designed for seamless coupling to the MS. The system must operate at flow rates ranging from at least 200 nL/min to 100 µL/min and must not require a flow splitter. b. The LC system must have the maximum operating pressure at least to 15,000 psi. c. The LC system must be capable of operating within a pH range of 2–10. d. The LC system must support two-dimensional (2D) LC analysis, including an auxiliary solvent and trap valve manager, a column-trapping pump, nano-Lock spray capability, primary check valves, column compartment, and switching valves configured for 2D operation. All primary wetted materials must be included. e. The LC system must support unattended operation, with full diagnostic data display for up to 96 hours through the control software. f. The LC system must include solvent storage, with a solvent tray capable of accommodating up to three (3) eluents. g. The LC system must include a micro-binary solvent delivery system, supporting solvents A1 or A2 and B1 or B2, and must provide solvent conditioning, gradient formation, primary check valves, compressibility compensation, and automatic priming. Pump compositional precision must be < 0.25% RSD based on repeated injections. The system must be equipped with an integrated, programmable active wash system to flush the rear of the high-pressure seals. h. The LC system must include a sample handling system with an injection volume range from 0.1 µL to 100 µL, with 5 µL standard injection, supporting 1, 2, 5, 20, 50, and 100 µL injection options, and unlimited volume for trapping. The system must have full-loop and partial-loop injection modes. The autosampler must accommodate 96- or 48-position sample plates with 2.0 mL vials and include a temperature-controlled autosampler (4.0–40.0 °C) with high temperature accuracy and stability. The system must have a column chamber (temperature controlled). i. All equipment must be certified or approved for use in accordance with the Canadian Electrical Code; j. The LC system must be CSA certified upon delivery.
Turn this listing into a bid decision.
Build a company profile to unlock match scoring, explanations, checklist next steps, saved opportunity tracking, and alerts.